Today data storage is dominated by the use of magnetic disks. Storage densities of about more than 5 Gb/cm 2 have been achieved. In the past 40 years areal density has increased by 6 orders of magnitude. But there is a physical limit. It has been predicted that superparamagnetic effects- the bit size at which stored information become volatile as a function of time- will limit the densities of current longitudinal recording media to about 15.5 Gb/cm2 . In the near future century nanometer scale will presumably pervade the field of data storage. In magnetic storage used today, there is no clear-cut way to achieve the nanometer scale in all three dimensions. So new techniques like holographic memory and probe based data storage are emerging. If an emerging technology is to be considered as a serious candidate to replace an existing technology, it should offer long-term perspectives. Any new technology with better areal density than today's magnetic storage should have long-term potential for further scaling, desirably down to nanometer or even atomic scale.

The only available tool known today that is simple and yet offer these long-term perspectives is a nanometer-sharp tip like in atomic force microscope (AFM) and scanning tunneling microscope (STM). The simple tip is a very reliable tool that concentrates on one functionality: the ultimate local confinement of interaction. In local probe based data storage we have a cantilever that has a very small tip at its end. Small indentations are made in a polymer medium laid over a silicon substrate. These indentations serve as data storage locations. A single AFM operates best on the microsecond time scale. Conventional magnetic storage, however, operates at best on the nanosecond time scale, making it clear that AFM data rates have to be improved by at least three orders of magnitude to be competitive with current and future magnetic recording. The "millipede" concept is a new approach for storing data at high speed and with an ultrahigh density.

Millipede Concept
Millipede is a highly parallel scanning probe based data storage that has a real storage densities far beyond superparamagnetic limits and data rates comparable to today's magnetic recording. At the first glance, millipede looks like a conventional 14 X 7 mm 2 silicon chip. Mounted at the center of the chip is a miniature two-dimensional array of 1024 'v'-shaped cantilevered arms that are 70 µm long and 0.5 µm thick. A nano-sharp fang-like tip, only 20 nm in diameter, hangs from the apex of each cantilever. The multiplex drivers, allow addressing of each tip individually. Beneath the cantilever array, is a thin layer of polymer film deposited on a movable, three-axis silicon table. The 2-D AFM cantilever array storage technique called "millipede" is based on a mechanical parallel x/y scanning of either the entire cantilever array chip or the storage medium.

In addition, a feedback-controlled z-approaching and leveling scheme brings the entire cantilever array chip into contact with the storage medium. The tip-medium contact is maintained and controlled while x/y scanning is performed for read/write. The millipede approach is not based on individual z-feedback for each cantilever ; rather it uses a feedback control for the entire chip, which greatly simplifies the system. However this requires very good control and uniformity of tip height and cantilever bending. Chip approach/leveling makes use of additionally integrated approaching cantilever sensors in the corners of the array chip to control the approach of the chip to the storage medium. Signals from these sensors provide feedback signals to adjust the z-actuators until contact with the medium is established. Feedback loops maintain the chip leveled and in contact with the surface while x/y scanning is performed for write/read operations.

Millipede Is Unique
Conventional data storage devices, such as disk drives and CD/DVDs, are based on systems that sense changes in magnetic fields or light to perform the read/write/store/erase functions. Millipede is unique both in form and the way it performs data storage tasks; it is based on a chip-mounted, mechanical system that senses a physical change in the storage media. The millipede's technology is actually closer to, although on an atomic scale, the archaic punched card than the more recent magnetic media. Using millipede, the IBM scientists have demonstrated a data storage density of a trillion bits per square inch -20 times higher than the densest magnetic storage available today. Millipede is dense enough to store the equivalent of 25 DVDs on a surface of the size of a postage stamp. This technology may boost the storage capacity of handheld devices - personal digital assistants (PDAs) and cell phones - often criticized for their low storage capabilities.

Comments

Popular posts from this blog

Poly Fuse

Polyfuse is a new standard for circuit protection. It is resettable. Many manufacturers also call it polyswitch or multifuse. Polyfuses are not fuses but polymeric positive temperature co-efficient (PPTC) thermistors. Current limiting can be accomplished by using resistors , fuses , switches or positive temperature co-efficient devices. Resistors are rarely an acceptable solution because the high power resistors that are usually required are expensive. One-shot fuses can be used, but they might fatigue, and they must be replaced after a fault event. Ceramic PTC devices tends to have high resistance and power dissipation characteristics. The preferred solution is a PPTC device which has low resistance in normal operation and high resistance when exposed to a fault. Electrical shorts or electrically over-loaded circuits can cause over-current and over temperature damage. Like traditional fuses , PPTC devices limit the flow of dangerously high current during fault conditions. Unlike tradi...

Daknet

Now a day it is very easy to establish communication from one part of the world to other. Despite this even now in remote areas villagers travel to talk to family members or to get forms which citizens in-developed countries an call up on a computer in a matter of seconds. The government tries to give telephone connection in very village in the mistaken belief that ordinary telephone is the cheapest way to provide connectivity. But the recent advancements in wireless technology make running a copper wire to an analog telephone much more expensive than the broadband wireless Internet connectivity. Daknet, an ad hoc network uses wireless technology to provide digital connectivity. Daknet takes advantages of the existing transportation and communication infrastructure to provide digital connectivity. Daknet whose name derives from the Hindi word "Dak" for postal combines a physical means of transportation with wireless data transfer to extend the internet connectivity that a upl...

Wearable Bio-Sensors

Wearable sensors and systems have evolved to the point that they can be considered ready for clinical application. The use of wearable monitoring devices that allow continuous or intermittent monitoring of physiological signals is critical for the advancement of both the diagnosis as well as treatment of diseases. Wearable systems are totally non-obtrusive devices that allow physicians to overcome the limitations of ambulatory technology and provide a response to the need for monitoring individuals over weeks or months. They typically rely on wireless miniature sensors enclosed in patches or bandages or in items that can be worn, such as ring or shirt. The data sets recorded using these systems are then processed to detect events predictive of possible worsening of the patient's clinical situations or they are explored to access the impact of clinical interventions. It is a pulse oximetry sensor that allows one to continuously monitor heart rate and oxygen saturation in a totally u...